4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable

Model NO.: 3 x AAC + 1 x AAAC
Material Shape: Round Wire
Range of Application: Overhead
Certification: ISO9001, CE, UL, CCC, RoHS, VDE
Brand: Jinshui
Rated Voltage: 0.6/1 Kv, 11kv, 33kv
Cores: Duplex, Triplex, Quadruplex
Type of Phase Conductor: AAC
Type of Neutral Conductor: AAC, AAAC, ACSR
Packaging: Wooden Drum
Color: Black
Insulation: XLPE
Core Materia: Aluminum
Key Words: Aerial Bounded Cable
Product Name: 4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable
Trademark: Jinshui
Transport Package: Export Wooden Drum, Iron-Wooden Drum, Soft Roll
Specification: ISO, CE, CCC
Origin: Zhengzhou Henan
HS Code: 8544492100
Model NO.: 3 x AAC + 1 x AAAC
Material Shape: Round Wire
Range of Application: Overhead
Certification: ISO9001, CE, UL, CCC, RoHS, VDE
Brand: Jinshui
Rated Voltage: 0.6/1 Kv, 11kv, 33kv
Cores: Duplex, Triplex, Quadruplex
Type of Phase Conductor: AAC
Type of Neutral Conductor: AAC, AAAC, ACSR
Packaging: Wooden Drum
Color: Black
Insulation: XLPE
Core Materia: Aluminum
Key Words: Aerial Bounded Cable
Product Name: 4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable
Trademark: Jinshui
Transport Package: Export Wooden Drum, Iron-Wooden Drum, Soft Roll
Specification: ISO, CE, CCC
Origin: Zhengzhou Henan
HS Code: 8544492100

======================================================                       *Product Description*  

====================================================== 
Specifications
* Standard: National Standard IEC and ASTM
* Rated Voltage: 0.6/1KV, 11KV, 33KV
* Construction: Phase conductor: Aluminum stranded(AAC)
* Neutral conductor: Aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel     reinforced(ACSR)
* Insulation: XLPE or PE
* Application: The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.
* Uesd for overhead service application such as street linghting, outdoor lighting and temporary service  for cunstruction. Which improves the safety and reliance of electrified wire netting.




Type: Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
A Duplex Service Drop

Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
B Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
C Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.


Construction
A Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
B Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
C Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75° C temperature rating is available upon request.


4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable

 

Code Name                       Phase Conductor              Bare Neutral Messenger Weight Per 
1000ft
(lbs)
Rating
(Amps)
Size
 AWG
Strand Insulation 
Thickness
(mls)
Size 
AWG
Strand Breaking 
Strength
(lbs)
XLPE Poly XLPE Poly
AAC NEUTRAL-MESSENGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.2 370 280
ACSR NEUTRAL-MESSENGER
Morochuca 6 Solid 45 6 6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 6/1 8,350 1,079 1,039.2 275 210
Bronco 336.4 19/w 80 336.4 18/1 8,580 1,613 1,568.2 370 280
Gelding 336.4 19/w 80 4/0 6/1 8,350 1,548 1,494.3 370 280

 BS 7870-5: Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV

ABC Cables without Street Lighting
1+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Electrical Resistance Section Insulation Thickness Electrical Resistance Overall Diameter Cable Weight
DC.20°C DC.20°C    
No.xmm2 mm Ω/km mm2 mm Ω/km mm kg/km
1x25 1.3 1.20 25 1.3 1.20 17.6 210
1x35 1.3 0.868 35 1.3 0.868 19.6 270
1x50 1.5 0.641 50 1.5 0.641 23 360
1x70 1.5 0.443 70 1.5 0.443 26.4 500
1x95 1.7 0.320 95 1.7 0.320 30.6 680
               
3+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Electrical Resistance Section Insulation Thickness Electrical Resistance Overall Diameter Cable Weight
DC.20°C DC.20°C    
No.xmm2 mm Ω/km mm2 mm Ω/km mm kg/km
3x25 1.3 1.20 25 1.3 1.20 21.2 410
3x35 1.3 0.868 35 1.3 0.868 23.7 550
3x50 1.5 0.641 50 1.5 0.641 27.8 730
3x70 1.5 0.443 70 1.5 0.443 31.9 1000
3x95 1.7 0.320 95 1.7 0.320 36.9 1370
3x120 1.7 0.253 120 1.7 0.253 40.6 1690
ABC Cables with Street Lighting
3+1+1 Structure
Phase Conductor Neutral Conductor Street Lighting Conductor Completed Cable
Section Insulation Thickness Section Insulation Thickness Section Insulation Thickness Overall Diameter Cable Weight
No.xmm2 mm mm2 mm mm2 mm mm kg/km
3x50 1.5 50 1.5 25 1.3 29.8 830
3x70 1.5 70 1.5 25 1.3 33.6 1100
3x95 1.7 95 1.7 25 1.3 38.2 1470

 Other standard and sizes can also be produced as you required.

4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable




 

======================================================                          *Company Description*  

======================================================  Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.

We have been engaged in producing electric cable and wire for nearly 20 years, and  we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .

Our product range is as following:
 
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
 *Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
 * PVC insulated wire (Rated voltage to 450/750V)
 *THHN/THWN wire
 *PVC insulated Power Cable
 *XLPE insulated Power Cable 
 *Rubber sheathed Cable 
 *Control Cable
 *Welding Cable 
 *Cable Accessories

We take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer's factory in Zhengzhou ,China . 
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.


4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable





===========================================================

                               * Our Factory * 
========================================================== 
1,Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.

2,We choose excellent raw materials carefully to ensure the quality and meet the need of customers.

3,Mechanical testing of Cables is done to determine the quality and mechanical characteristics  before delivery.


4,Packaging and Shipping
We have a professional handling equipment to ensure the delivery of products.
Inner packing: wooden drum, iron wooden drum and iron drum.
Outer packing: 20',40' container 

Other packages are available according to client's request

We always pack and load the products according to the customers' demand, and we have rich experience on it.
4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable
4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable


4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable



====================================================== 
                                     *FAQ*      
====================================================== 
(1)Are  you the factory or trading company?
We are the manufacturer and 12 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
 (2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.





              Welcome your kind enquiry!

======================================================                       *Product Description*  

====================================================== 
Specifications
* Standard: National Standard IEC and ASTM
* Rated Voltage: 0.6/1KV, 11KV, 33KV
* Construction: Phase conductor: Aluminum stranded(AAC)
* Neutral conductor: Aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel     reinforced(ACSR)
* Insulation: XLPE or PE
* Application: The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.
* Uesd for overhead service application such as street linghting, outdoor lighting and temporary service  for cunstruction. Which improves the safety and reliance of electrified wire netting.




Type: Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
A Duplex Service Drop

Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
B Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
C Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.


Construction
A Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
B Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
C Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75° C temperature rating is available upon request.


4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable

 

Code Name                       Phase Conductor              Bare Neutral Messenger Weight Per 
1000ft
(lbs)
Rating
(Amps)
Size
 AWG
Strand Insulation 
Thickness
(mls)
Size 
AWG
Strand Breaking 
Strength
(lbs)
XLPE Poly XLPE Poly
AAC NEUTRAL-MESSENGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.2 370 280
ACSR NEUTRAL-MESSENGER
Morochuca 6 Solid 45 6 6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 6/1 8,350 1,079 1,039.2 275 210
Bronco 336.4 19/w 80 336.4 18/1 8,580 1,613 1,568.2 370 280
Gelding 336.4 19/w 80 4/0 6/1 8,350 1,548 1,494.3 370 280

 BS 7870-5: Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV

ABC Cables without Street Lighting
1+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Electrical Resistance Section Insulation Thickness Electrical Resistance Overall Diameter Cable Weight
DC.20°C DC.20°C    
No.xmm2 mm Ω/km mm2 mm Ω/km mm kg/km
1x25 1.3 1.20 25 1.3 1.20 17.6 210
1x35 1.3 0.868 35 1.3 0.868 19.6 270
1x50 1.5 0.641 50 1.5 0.641 23 360
1x70 1.5 0.443 70 1.5 0.443 26.4 500
1x95 1.7 0.320 95 1.7 0.320 30.6 680
               
3+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Electrical Resistance Section Insulation Thickness Electrical Resistance Overall Diameter Cable Weight
DC.20°C DC.20°C    
No.xmm2 mm Ω/km mm2 mm Ω/km mm kg/km
3x25 1.3 1.20 25 1.3 1.20 21.2 410
3x35 1.3 0.868 35 1.3 0.868 23.7 550
3x50 1.5 0.641 50 1.5 0.641 27.8 730
3x70 1.5 0.443 70 1.5 0.443 31.9 1000
3x95 1.7 0.320 95 1.7 0.320 36.9 1370
3x120 1.7 0.253 120 1.7 0.253 40.6 1690
ABC Cables with Street Lighting
3+1+1 Structure
Phase Conductor Neutral Conductor Street Lighting Conductor Completed Cable
Section Insulation Thickness Section Insulation Thickness Section Insulation Thickness Overall Diameter Cable Weight
No.xmm2 mm mm2 mm mm2 mm mm kg/km
3x50 1.5 50 1.5 25 1.3 29.8 830
3x70 1.5 70 1.5 25 Remote Switch

REMOTE CONTROL SOCKET
Important Safeguards
When using any electrical appliance, in order to reduce the risk of fire, electric shock and/or injury to persons, basic safety precautions should always be follow8d. including:
• The appliance is for household and indoor use only.
• Before plugging in. check that the voitage on the rating label is the same as the mains supply.
• To protect against electric shock, do not immerse any part of the product in water or other liquid.
• This socket is intended for use by competent adults only and children should be supervised at all times.
• Do not use the socket for other than its intended use.
• This socket can be used by children aged from 8 years arxl above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not p<ay with the appliance Cleaning and user maintenance shall M be made by children without supervision.
• Children of less than 3 years should be kept away unless continuously supervised.
Children from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in. regulate and clean the appliance or perform user maintenance.
• Don't use this socket in the immediate surroundings of a bath, a shower or a swimming pool.
• In case of malfunction, do not try to repair the socket yourself, it may result in a fire hazard or electric shock
Do Not Exceed Maximum a680W
Place the LR44 batteries provided into the compartment in the back of the Remote Control, please
insert as sho*/m in the back of the compartment to ensure the polarity is correct.

Programming Instructions
• Plug the Remoce Socket$($)lnto the wall socket(s) and switch on the mams supply, the red LED will flash every second.
• If the LED is not flashing press & hold the manual ON/OFF button for 5 seconds until it Hashes

•Press any ON switch on the Remote Control for approximately 2 seconds and the Remote Socket(s) learn the code. The LED will stop flashing top confirm the codehas been accepted.
• Any number of Remote Sockets can be programmed to one Remote Control ON button to create multiple switching.
• To programme o<her Remote Sockets on different Remote Control ON buttons repeat the prevous steps
• If the mains supply is turned off the Remote Sockets v/ill lose their code and it wil be necessary to re-pcogramme.
Operation:
• Plug your appliance(s) into the Remote Socket(s)
• Press the programmed ON or OFF button on the Remote Control to control the Remote Socket.
♦ The Remote Sockets can also be operated manually using its ON/OFF Button Trouble shooting
If a Remote Socket does not react to the Remote Control please check the followng:
♦ Low battery in tbo Remote Control
• Distance too large between the remote control and the recerver (ensure the range distance is no more than 20 clear Metres) and free from obstacle that may reduce the distance.
• If programming has not been successful, tum the power off and back on then follow the programming steps above.
How to decode
• Press the manual ONX)FF button for 5 seconds until the red LED flashes once per
second to confirm de-coding is successful
♦ Press the ALL OFF switch on the Remote Control for more than 3 seconds, the LED
flashes once per second to confirm (decoding successful.
Voltage: 240V-/50HZ
Max power rating: 3680W max.
Remote frequency:
Remote range:
Battery Type:
433.92MHz
230 Metres
Button Cell 2x1.5V LR44 =
Please check with your local waste management service authority regarding regulations for the safe disposal of the batteries. The batteries should never be placed G municipal waste.
Use a battery d^posal facility if available
M
For eioctncal products sold within the European Community. At the end of the electrical products useful life, it should not be disposed of wth household waste. Please recycle faaMies exist. Check with your Local Authonty or retailer for recycling advice.
C€

remote switch,remote plug,remote control switch,remote power switch,remote control sockets

NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsocket.com