(1) The mnemonic, instruction code, operand and program steps of the batch reset instruction are listed in Table 6-38.
LED power supply, CCTV center power supply device, LCD display power supply.
We can meet your specific requirement of the products, like label design. The plug type is US/UK/AU/EU. The material of this product is PC+ABS. All condition of our product is 100% brand new. OEM and ODM are available in our company, and you deserve the best service. You can send more details of this product, so that we can offer best service to you!
Power Supply,5V Power Supply,12V Power Supply, 24V Power Supply Shenzhen Waweis Technology Co., Ltd. , https://www.waweispowerasdapter.com
(2) The command ladder diagram is shown in Figure 6-67.
(3) Instruction description:
1 The function of this command is to clear all the devices in the specified interval to "0".
2[D1], [D2] The two operands are the same device, and the address number of [D1] is ≤ [D2]. When the address number of [D1] is the address number of [D2], only the device specified by [D1] is reset.
3 This instruction is generally only for 16-bit processing, but can be specified to reset the 32-bit counter. In this case, both operands must be 32-bit counters. If one 16-bit and the other 32-bit, the program will fail.