Model NO.: Indoor distribution cable
Core: Double Core
Certification: RoHS, UL, CE, ISO9001
Brand: OEM
Sheath Material: LSZH
Mode: Single Mode
Central Member: Mentallic Strength Member
Operating Temperature: -40 C ~ +70 C
Filling Gel: Water Blocking
Install Style: Outdoor Direct Buried
Armor: Steel Armoring
Core Number: Customized
Number of Conductors: up to 10
Brand Name: Tw-Scie Fiber Optic Cable or as Required
Trademark: TW-SCIE or OEM
Transport Package: Wooden Drum
Specification: ROHS, CE
Origin: Guangdong Dongguan
HS Code: 854470000
Model NO.: Indoor distribution cable
Core: Double Core
Certification: RoHS, UL, CE, ISO9001
Brand: OEM
Sheath Material: LSZH
Mode: Single Mode
Central Member: Mentallic Strength Member
Operating Temperature: -40 C ~ +70 C
Filling Gel: Water Blocking
Install Style: Outdoor Direct Buried
Armor: Steel Armoring
Core Number: Customized
Number of Conductors: up to 10
Brand Name: Tw-Scie Fiber Optic Cable or as Required
Trademark: TW-SCIE or OEM
Transport Package: Wooden Drum
Specification: ROHS, CE
Origin: Guangdong Dongguan
HS Code: 854470000
Tight Buffer Fiber Optic Cable (GJBFJV) with 24 Core Indoor BreakoutÂ
Product Description
These cables are constructed bundling tight buffered simplex optical fiber in an outer jacket. Non metallic FRPÂ
strength members in the cable give it good tensile strength and electro-magnetic protection. It has small diameter,Â
light weight and thick wall jacket protection, giving it versatile applications. It can be used in cable assembliesÂ
and places of high electro-magnetic interferences.Â
Flexible and small bent radius ensures good performance against pressure. These simplex cables are individuallyÂ
reinforced with Aramid yarn so can be terminated without the need for breakout boxes, patch panel or junction boxes.Â
Each fiber is mechanically reinforced with two successive sheaths of 400µm and 900µm which enables directÂ
termination of connectors. Excellent strip force stability, fiber geometrical dimension and transmission performanceÂ
meets the customer demand. Available in PVC, LSZH, Plenum outer sheath and tight buffer: 900µm, 600µm. TheÂ
cable is specially designed for  indoor applications like oor distribution, interconnection and equipment connection.Complied With Or Exceeds Standard
.  ITU-T G652.D                                      .  ITU-T G651.1 OM1 OM2 OM3 OM4Â
.  ITU-T G657.A                                      .  IEC60793-2-10  type A1a.1/A1b OM1/OM2
.  IEC60793-2-10  type A1a.2 OM3        .  IEC60793-2-10  type A1a.3 OM4
.  ISO/IEC 11801 , ISO/IEC 24702         .  IEEE 802.3z Gigabit Ethernet
.  ANSI/TIA/EIA 568C.3                          .  ROHS Compliant Directive 2011/65/EU(ROHS2.0)Mechanical & Environmental Characteristics
ITEM |
Value |
Max. Tensile Load (Short Term) |
1500N |
Max. Tensile Load (Long Term) |
600N |
Max. Crush Load (Short Term) |
1000N/100mm |
Max Crush Load (Long Term) |
300N/100mm |
UL Fire Rated |
OFNR |
Operating Temperature |
-20°C to +60°C |
Storage Temperature |
-40°C to +85°C |
Sheath Material |
Standard: PVC    Optional: LSZH, PE or other |
Standard Fiber Color Code
Fiber Number   Fiber Color   Fiber Number   Fiber Color
 Fiber 1          Blue         Fiber 7        Red
 Fiber 2        Orange        Fiber 8        Black
 Fiber 3         Green        Fiber 9       Yellow
 Fiber 4        Brown         Fiber 10      Violet
 Fiber 5         Slate         Fiber 11       Rose
 Fiber 6        White         Fiber 12       Aqua
Fiber 13 and higher The color code is repeated with added black stripe or dash
Note: Fiber Tube color will be followed with same order.Optical CharacteristicsÂ
Of all the differences between multimode & singlemode fiber, the most fundamental differences are theÂ
size of the fiber's core and the associated attenuation or loss and bandwidth of the fiber. The smaller theÂ
core diameter, the higher the fiber's bandwidth and the lower the attenuation (loss in dB per kilometer).Â
The fiber's attenuation and bandwidth are also dependent on wavelength.Â
Â
Singlemode was for high-speed longdistance transmission and multimode (in either the 50 µm or 62.5 µmÂ
core diameters) was used for lower speed short distance applications. Multimode 50 µm fiber had a lowerÂ
cost and higher modal bandwidth than multimode 62.5 µm core fiber. Bandwidth is a measurement of theÂ
data carrying capacity of the fiber. A higher bandwidth fiber carries more data. See table below.Â
Fiber Type |
Max. Attenuation (dB/km) |
Min.Overfill Launch Bandwidth (Mhz.km) |
Min.Gigabit Ethernet Link Distance (m) |
Gigabit |
10Gigabit |
850nm |
1300nm |
1310nm |
1550nm |
850nm |
1300nm |
850nm |
1300nm |
850nnm |
OM1 62.5/125µm |
≤2.7 |
≤0.6 |
- |
- |
≥500 |
≥600 |
275 |
550 |
- |
OM2 50/125µm |
≤2.3 |
≤0.6 |
- |
- |
≥500 |
≥500 |
750 |
600 |
150 |
OM3 50/125µm |
≤2.3 |
≤0.6 |
- |
- |
≥1500 |
≥500 |
1000 |
600 |
300 |
OM4 50/125µm |
≤2.3 |
≤0.6 |
- |
- |
≥3500 |
≥500 |
1100 |
600 |
550 |
G652D 9/125µm |
- |
- |
≤0.30 |
≤0.18 |
- |
- |
- |
- |
- |
G657A 9/125µm |
- |
- |
≤0.35 |
≤0.21 |
- |
- |
- |
- |
- |
Ordering Information
Part Number: OC-XX-ABCDCL
Â
Ordering Guide
XX |
A |
B |
C |
D |
CL |
Cable Type |
Jacket |
Fiber/Sub |
Fiber Count |
Fiber Type(FXX) |
Jacket Color(CL) |
 GJBFJV |
1=PVC 2=LSZH 3=PE |
01=01Â Fiber/S 02=02Â Fiber/S ... 11=11Â Fiber/S 12=12Â Fiber/S |
No. Of Fiber 004F,048F |
OM1=62.5/125Â OM1 OM2=50/125Â OM2 OM3=50/125Â OM3 OM4=50/125Â OM4 G652D=9/125Â G652D G657A=9/125Â G657A |
As noted in Color code chart |
Ordering Sample
Part Number |
Description |
OC-GJBFJV-2124G652DYE |
24 cores Singlemode G652D GJBFJV Fiber Optic Cable, 1 Fiber/Sub, LSZH jacket, Yellow color. |
Tag:Â Tight Buffer Fiber Optic Cable (GJBFJV) ,24 Core Indoor BreakoutÂ
Tight Buffer Fiber Optic Cable (GJBFJV) with 24 Core Indoor BreakoutÂ
Product Description
These cables are constructed bundling tight buffered simplex optical fiber in an outer jacket. Non metallic FRPÂ
strength members in the cable give it good tensile strength and electro-magnetic protection. It has small diameter,Â
light weight and thick wall jacket protection, giving it versatile applications. It can be used in cable assembliesÂ
and places of high electro-magnetic interferences.Â
Flexible and small bent radius ensures good performance against pressure. These simplex cables are individuallyÂ
reinforced with Aramid yarn so can be terminated without the need for breakout boxes, patch panel or junction boxes.Â
Each fiber is mechanically reinforced with two successive sheaths of 400µm and 900µm which enables directÂ
termination of connectors. Excellent strip force stability, fiber geometrical dimension and transmission performanceÂ
meets the customer demand. Available in PVC, LSZH, Plenum outer sheath and tight buffer: 900µm, 600µm. TheÂ
cable is specially designed for  indoor applications like oor distribution, interconnection and equipment connection.Complied With Or Exceeds Standard
.  ITU-T G652.D                                      .  ITU-T G651.1 OM1 OM2 OM3 OM4Â
.  ITU-T G657.A                                      .  IEC60793-2-10  type A1a.1/A1b OM1/OM2
.  IEC60793-2-10  type A1a.2 OM3        .  IEC60793-2-10  type A1a.3 OM4
.  ISO/IEC 11801 , ISO/IEC 24702         .  IEEE 802.3z Gigabit Ethernet
.  ANSI/TIA/EIA 568C.3                          .  ROHS Compliant Directive 2011/65/EU(ROHS2.0)Mechanical & Environmental Characteristics
ITEM |
Value |
Max. Tensile Load (Short Term) |
1500N |
Max. Tensile Load (Long Term) |
600N |
Max. Crush Load (Short Term) |
1000N/100mm |
Max Crush Load (Long Term) |
300N/100mm |
UL Fire Rated |
OFNR |
Operating Temperature |
-20°C to +60°C |
Storage Temperature |
-40°C to +85°C |
Sheath Material |
Standard: PVC    Optional: LSZH, PE or other |
Standard Fiber Color Code
Fiber Number   Fiber Color   Fiber Number   Fiber Color
 Fiber 1          Blue         Fiber 7        Red
 Fiber 2        Orange        Fiber 8        Black
 Fiber 3         Green        Fiber 9       Yellow
 Fiber 4        Brown         Fiber 10      Violet
 Fiber 5         Slate         Fiber 11       Rose
 Fiber 6        White         Fiber 12       Aqua
Fiber 13 and higher The color code is repeated with added black stripe or dash
Note: Fiber Tube color will be followed with same order.Optical CharacteristicsÂ
Of all the differences between multimode & singlemode fiber, the most fundamental differences are theÂ
size of the fiber's core and the associated attenuation or loss and bandwidth of the fiber. The smaller theÂ
core diameter, the higher the fiber's bandwidth and the lower the attenuation (loss in dB per kilometer).Â
The fiber's attenuation and bandwidth are also dependent on wavelength.Â
Â
Singlemode was for high-speed longdistance transmission and multimode (in either the 50 µm or 62.5 µmÂ
core diameters) was used for lower speed short distance applications. Multimode 50 µm fiber had a lowerÂ
cost and higher modal bandwidth than multimode 62.5 µm core fiber. Bandwidth is a measurement of theÂ
data carrying capacity of the fiber. A higher bandwidth fiber carries more data. See table below.Â
Fiber Type |
Max. Attenuation (dB/km) |
Min.Overfill Launch Bandwidth (Mhz.km) |
Min.Gigabit Ethernet Link Distance (m) |
Gigabit |
10Gigabit |
850nm |
1300nm |
1310nm |
1550nm |
850nm |
1300nm |
850nm |
1300nm |
850nnm |
OM1 62.5/125µm |
≤2.7 |
≤0.6 |
- |
- |
≥500 |
≥600 |
275 |
550 |
- |
OM2 50/125µm |
≤2.3 |
≤0.6 |
- |