Automatic pressure regulating concrete impermeability meter

experiment procedure:


1

The test piece is formed and cured. It is formed by forming mold (also called sub-mold) according to the material ratio required by the design, and then cured according to the specifications of the Ministry or international standards.


2

The test body was taken out of the curing room one day before the test, and the test mold was heated to

40

°C

The left and right sides of the wax are heated to completely melt, and then the circumference of the test piece is rolled in the solution for one week (the wax is strictly prohibited on both ends of the test piece), and the sample with the wax is pressed into the test piece by a press.


3

Penetration test


(

1

) Irrigation: Unscrew the nut of the water injection nozzle, open each door at the same time, place the funnel on the water injection nozzle, fill the water tank to fill it, and require the test mold chassis to be filled with water (the role is to exclude the tube) Air in the road system) At this time, six cut-off doors leading to the test mold can be closed.


(

2

) Installation of test mode: The test piece of the sealed test piece is securely mounted on the instrument.


(

3

At the time of the test: according to the new specification

twenty four

After the hour is finished, for example, the project requires the test block to be pressurized.

0.8MPa

, the lower limit is set to

0.6MPa

Constant pressure

8

After the hour, the lower limit is automatically boosted to

0.7MPa

And constant pressure

8

Hour, the lower limit is automatically boosted to

0.8MPa

,

8

Finished after hours.


(

4

) when the end faces of the six specimens have

2

When the water is permeated by the pressurized water, the water pressure at this time is recorded as the pressure value of the test.



Piezoelectric Elements For Inkjet Piezo Transducer

Piezoelectric ceramic ring



Applications: ultrasonic vibration tranducer for inkjet printer



Vibration mechanism of inkjet printer:

Generally, it is composed of piezoelectric ceramics and driving rods. By high-frequency electric excitation, piezo ceramics produce high-frequency ultrasonic vibration (above 60 kHz or higher), which is transmitted to the driving rod and generates high-frequency micro-displacement (back and forth expansion) at its front end.

Piezo ceramics components features :

1. High vibration amplitude and can withstand higher power.
2. The product has high reliability, strong maintainability, and is not easy to break down or off-line.
3. The frequency can be adjusted in a wide range, generally within the range of 10KHz.





Yuhai support all the new developping transducer, Welcome the customized elements inquiry.




The present piezoelectric elements for Inkjet piezo transducer is following :



Piezo rings OD4*ID2*2.5mm price USD1.20/pc, 2000pcs
Material: PBaS-4
Fr.: 694 KHz ±5KHz
K33: ≥0.55
Tg loss <0.5%
Ct 60pF ±12.5%

Piezo rings OD4*ID2*2.5mm price USD1.20/pc, 2000pcs
Material: PSnN-5
Fr.: 626KHz ±5KHz
K33: ≥0.57
Tg loss < 2%
Ct 53pF ±12.5%

Piezo rings OD6*ID2.5*2mm price USD1.50/pc, 2000pcs
Material: PZT-41
Fr.: 785 KHz ±5KHz
K33: >0.53
Tg loss < 0.5%
Ct 107 pF ±12.5%

Piezo rod OD3*7mm price USD1.20/pc, 2000pcs
Material: PLiS-51
Fr.: 192 KHz ± 3KHz
K33: >0.62
Tg loss < 2%
Ct 18.7 pF ±12.5%




Inkjet Piezo Transducer,Piezoelectric Vibration Transducer,Piezoelectric Rings,Piezoelectric Elements For Inkjet Piezo Transducer

Zibo Yuhai Electronic Ceramic Co., Ltd. , https://www.yhpiezo.com